At Aseptic Lab Nexus, we proudly introduce our Reverse Laminar Air Flow (RLAF) system, designed for top-tier contamination control in critical environments. Our RLAF units use high-efficiency particulate air (HEPA) filters to remove 99.99% of airborne contaminants, ensuring a clean and safe workspace. The reverse airflow design pulls air away from the operator and work area, boosting safety and hygiene. Perfect for pharmaceutical manufacturing, biotechnology, and laboratory applications, our RLAF systems are built with durable materials and feature easy-to-use controls. Choose Aseptic Lab Nexus for innovative, reliable, and effective contamination control solutions.

Working Principle of Reverse Laminar Air Flow
The working principle of the Reverse Laminar Air Flow (RLAF) system involves creating a contamination-free environment by directing airflow in a reverse pattern. Ambient air is initially drawn into the unit through a pre-filter, which captures larger particles. The air then passes through high-efficiency particulate air (HEPA) filters, which effectively remove 99.99% of airborne contaminants as small as 0.3 microns. This filtered air is directed downward, creating a reverse airflow pattern that pulls air away from the operator and the work area. By doing so, it ensures that any contaminants are immediately swept away from the critical workspace and exhausted safely, thereby minimizing the risk of cross-contamination. The RLAF system’s design includes durable construction, energy-efficient fans, and user-friendly controls to maintain consistent airflow and ensure reliability. This setup is crucial for applications that require stringent contamination control, such as pharmaceutical manufacturing, biotechnology, and various laboratory environments. By maintaining a clean and sterile environment, the RLAF system from Aseptic Lab Nexus provides.
Reverse Laminar Air Flow Cabinets Manufacturers in India
At Aseptic Lab Nexus, we are a premier manufacturer of Reverse Laminar Air Flow (RLAF) systems, offering advanced solutions for maintaining contamination-free environments across all states of India. Our RLAF units are expertly designed to meet the highest standards of cleanliness and safety, using state-of-the-art technology to ensure optimal performance. Our RLAF systems utilize high-efficiency particulate air (HEPA) filters to remove 99.99% of airborne contaminants as small as 0.3 microns, creating a sterile workspace ideal for critical applications. The innovative reverse airflow design directs clean, filtered air downward, away from the operator and work area, effectively minimizing the risk of cross-contamination. We cater to diverse industries, including pharmaceutical manufacturing, biotechnology, and laboratory research, providing tailored solutions for a variety of contamination control needs. Choose Aseptic Lab Nexus for top-quality RLAF systems and exceptional service across India.
Safety Precautions to follow while operating Reverse laminar air flow Cabinet
When operating a Reverse Laminar Air Flow (RLAF) system, it’s essential to follow these safety precautions to ensure effective contamination control and maintain a safe working environment:
- Personal Protective Equipment (PPE): Wear appropriate PPE such as lab coats, gloves, and masks to protect yourself and prevent contamination of the workspace.
- Training: Ensure that all operators are properly trained on the use of the RLAF system and understand the safety protocols.
- Workspace Cleanliness: Keep the RLAF work surface clean and free of unnecessary items to maintain effective airflow and avoid contamination.
- Hand Hygiene: Wash and sanitize hands thoroughly before and after working in the RLAF environment to prevent the introduction of contaminants.
- Avoid Obstructions: Do not block the airflow grills or filters to ensure proper laminar flow and prevent disruptions in the clean environment.
- Filter Maintenance: Regularly inspect and replace pre-filters and HEPA filters as recommended to maintain the system’s effectiveness.
- Proper Airflow Management: Do not open the RLAF unit’s doors while it is operating to maintain the sterile environment.
- Airflow Verification: Regularly check the airflow velocity and patterns to ensure they remain within the specified range for effective contamination control.
- UV Light Safety: If the RLAF system includes a UV germicidal lamp, avoid direct exposure to UV light and ensure the lamp is turned off during use.
- Regular Maintenance: Follow the manufacturer’s guidelines for regular maintenance and servicing to ensure the system operates efficiently and safely.
- Emergency Procedures: Be familiar with emergency procedures for equipment malfunctions or contamination incidents.
By adhering to these safety precautions, you can ensure the safe and effective operation of your RLAF system, maintaining a clean and controlled environment for your critical processes.
Application Of Reverse Laminar Air Flow
- Pharmaceutical Manufacturing: Ensures a sterile environment for the preparation of drugs, handling of raw materials, and filling processes.
- Biotechnology Research: Provides a clean workspace for cell culture, microbiological studies, and the development of biological products.
- Laboratory Experiments: Supports contamination-free environments for various scientific experiments and research activities.
- Medical Device Manufacturing: Maintains a sterile environment for the production and assembly of medical devices and equipment.
- Clinical Diagnostics: Ensures a clean environment for diagnostic sample processing and analysis in clinical laboratories.
- Aseptic Processing: Critical for sterile operations in the production of aseptic products like vaccines and injectable drugs.
- Cleanroom Operations: Ideal for maintaining a controlled, contaminant-free environment in cleanroom settings.
- Electronics Assembly: Protects sensitive electronic components from airborne contaminants during assembly and testing processes.
- Food and Beverage Industry: Maintains hygiene and prevents contamination in the production of packaged food and beverages.
- Environmental Monitoring: Provides a controlled environment for environmental testing and monitoring.
- Forensic Analysis: Ensures a contamination-free environment for the collection and analysis of forensic evidence.
- Cosmetic Manufacturing: Ensures a sterile environment for the production and packaging of cosmetic products.
Key Feature Of ALN Reverse Laminar Air Flow
- High-Efficiency Filtration: HEPA/ULPA filters with 99.99% efficiency.
- Reverse Airflow Design: Clean air flows downward, protecting the workspace.
- Durable Construction: Made from stainless steel or powder-coated steel.
- User-Friendly Controls: Digital panel for easy operation and monitoring.
- Energy-Efficient Operation: Low power consumption with efficient fans and motors.
- Cleanroom Certification: Compliant with ISO 14644-1 Class 5 standards.
- Adjustable Airflow Velocity: Customizable settings for various applications.
- Easy Maintenance: Accessible filters for regular upkeep.
- UV Light Option: Optional UV lamp for additional sterilization.
- Visual Indicators: Alerts for filter status and system performance.
- Ergonomic Design: Comfortable and functional workspace.
- High Airflow Efficiency: Consistent, uniform air distribution.
Standard Dimensions Of Reverse Laminar Air Flow
Model | Internal Dimentions (W X D X H) mm | External Dimentions (W X D X H) mm | NO of Hepa filter |
ALN RLAF 42 | 1210 X 610 X 2000 | 1330 X 1410 X 2550 | 1 Nos. |
ALN RLAF 43 | 1210 X 915 X 2000 | 1035 X 1715 X 2550 | 1 Nos. |
ALN RLAF 44 | 1220 X 1220 X 2000 | 1340 X 2020 X 2550 | 1 Nos. |
ALN RLAF 54 | 1545 X 1220 X 2000 | 1035 X 2020 X 2550 | 2 Nos. |
ALN RLAF 55 | 1545 X 1545 X 2000 | 1340 X 2345 X 2550 | 4 Nos. |
ALN RLAF 66 | 1850 X 1850 X 2000 | 1340 X 2650 X 2550 | 4 Nos. |
Specifications Of Reverse Laminar Air Flow
- HEPA Filter – Supply (99.999% down to 0.3 micron)
- INTERMEDIATE Filter – Supply / Exhaust (95% down to 3 micron)
- Prefilter (95% down to 5 micron)
- Triple Stage filtration
- Powder coated Mild Steel, SS 304 / SS 316 / SS 316L or a combination of both
- SS 304 Double walled Side Panels
- Differential Pressure Gauge : 3 Nos to monitor pressure drop across three stages of filters.
- Maximum protection from airborne contaminants produced at the time of powder handling operations such as charging, sampling, and dispensing
- Down flow booth functions on a recirculatory airflow principle
- Balanced Motor-blower with suspension arrangement for diminishing the noise level
- Internal covings for easy cleaning
- Fluorescent Light
- DOP Test port at upstream of HEPA filter
- On / Off Switch for Motor
- 5/15 Amp Switch Socket for external equipment